Introduction While patching ODAs from 19.10 to 19.13, the update-dbhome could fail if some databases inside this dbhome are stopped or only mounted. Job would then stop with a DCS-10001:Internal error encountered: PRGH-1153 : RHPHelper call to get runing nodes(…)