{"id":21931,"date":"2023-01-24T19:42:54","date_gmt":"2023-01-24T18:42:54","guid":{"rendered":"https:\/\/www.dbi-services.com\/blog\/?p=21931"},"modified":"2023-06-20T10:22:43","modified_gmt":"2023-06-20T08:22:43","slug":"upgrade-oem-13c-from-r4-to-r5","status":"publish","type":"post","link":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/","title":{"rendered":"Upgrade OEM 13c from R4 to R5"},"content":{"rendered":"\n<p><strong>By Mouhamadou Diaw<\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>Upgrading Enterprise Manger Cloud Control can be tricky. In this blog I am describing an upgrade I did for a client.<\/p>\n\n\n\n<p>The source version is OEM13c R4<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"442\" height=\"247\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png\" alt=\"\" class=\"wp-image-21932\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png 442w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01-300x168.png 300w\" sizes=\"auto, (max-width: 442px) 100vw, 442px\" \/><\/figure>\n\n\n\n<p>And the target version will be EM13c R5<\/p>\n\n\n\n<p>Before starting I did following tasks<\/p>\n\n\n\n<p>-Copy the key in the repository<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>oracle@oemserverp01:\/home\/oracle\/emc135\/ &#091;oms13cR4] emctl config emkey -copy_to_repos\nOracle Enterprise Manager Cloud Control 13c Release 4\nCopyright (c) 1996, 2020 Oracle Corporation.  All rights reserved.\nEnter Enterprise Manager Root (SYSMAN) Password :\nThe EMKey has been copied to the Management Repository. This operation will cause the EMKey to become unsecure.\nAfter the required operation has been completed, secure the EMKey by running \"emctl config emkey -remove_from_repos\".\noracle@oemserverp01:\/u00\/app\/oracle\/product\/13.1.0.0\/swlib\/ &#091;oms13cR4]\n\n<\/code><\/pre>\n\n\n\n<p>-set the parameter &#8220;_allow_insert_with_update_check&#8221; to true<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>SQL&gt; alter system set \"_allow_insert_with_update_check\"=true scope=both;\n\nSystem altered.\n\nSQL&gt;\n<\/code><\/pre>\n\n\n\n<p>You can now stop the oms. Anyway the upgrade tool will ask you to do this when needed<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>oracle@oemserverp01:\/home\/oracle\/ &#091;oms13cR4] emctl stop oms -all\nOracle Enterprise Manager Cloud Control 13c Release 4\nCopyright (c) 1996, 2020 Oracle Corporation.  All rights reserved.\nStopping Oracle Management Server...\nWebTier Successfully Stopped\nOracle Management Server Successfully Stopped\nOracle Management Server is Down\nJVMD Engine is Down\nStopping BI Publisher Server...\nBI Publisher Server Successfully Stopped\nAdminServer Successfully Stopped\nBI Publisher Server is Down\noracle@oemserverp01:\/home\/oracle\/ &#091;oms13cR4] emctl status oms\nOracle Enterprise Manager Cloud Control 13c Release 4\nCopyright (c) 1996, 2020 Oracle Corporation.  All rights reserved.\nWebTier is Down\nOracle Management Server is Down\nJVMD Engine is Down\nBI Publisher Server is Down\noracle@oemserverp01:\/home\/oracle\/ &#091;oms13cR4]\n<\/code><\/pre>\n\n\n\n<p>Following zip files are downloaded.<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>oracle@oemserverp01:\/home\/oracle\/emc135\/ &#091;EMRE13C] ll\ntotal 8363828\n-rw-r--r--. 1 oracle oinstall 1897494675 Jan 23 09:22 em13500_linux64-2.zip\n-rw-r--r--. 1 oracle oinstall 2130750885 Jan 23 09:26 em13500_linux64-3.zip\n-rw-r--r--. 1 oracle oinstall 1454982045 Jan 23 09:29 em13500_linux64-4.zip\n-rw-r--r--. 1 oracle oinstall 1494500710 Jan 23 09:31 em13500_linux64-5.zip\n-rwxr-xr-x. 1 oracle oinstall 1586801533 Jan 23 09:19 em13500_linux64.bin\noracle@oemserverp01:\/home\/oracle\/emc135\/ &#091;EMRE13C]\n<\/code><\/pre>\n\n\n\n<p>To launch the upgrade run the executable &nbsp;em13500_linux64.bin (do chmod +x em13500_linux64.bin)<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>oracle@oemserverp01:\/home\/oracle\/emc135\/ &#091;rdbms19c] pwd\n\/home\/oracle\/emc135\noracle@oemserverp01:\/home\/oracle\/emc135\/ &#091;rdbms19c] .\/em13500_linux64.bin\n<\/code><\/pre>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"587\" height=\"463\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture39.png\" alt=\"\" class=\"wp-image-21948\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture39.png 587w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture39-300x237.png 300w\" sizes=\"auto, (max-width: 587px) 100vw, 587px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"595\" height=\"465\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture40.png\" alt=\"\" class=\"wp-image-21949\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture40.png 595w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture40-300x234.png 300w\" sizes=\"auto, (max-width: 595px) 100vw, 595px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"588\" height=\"465\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture41.png\" alt=\"\" class=\"wp-image-21950\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture41.png 588w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture41-300x237.png 300w\" sizes=\"auto, (max-width: 588px) 100vw, 588px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"593\" height=\"474\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture42.png\" alt=\"\" class=\"wp-image-21951\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture42.png 593w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture42-300x240.png 300w\" sizes=\"auto, (max-width: 593px) 100vw, 593px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"590\" height=\"466\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture43.png\" alt=\"\" class=\"wp-image-21952\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture43.png 590w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture43-300x237.png 300w\" sizes=\"auto, (max-width: 590px) 100vw, 590px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"591\" height=\"467\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture44.png\" alt=\"\" class=\"wp-image-21953\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture44.png 591w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture44-300x237.png 300w\" sizes=\"auto, (max-width: 591px) 100vw, 591px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"583\" height=\"337\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture45.png\" alt=\"\" class=\"wp-image-21954\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture45.png 583w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture45-300x173.png 300w\" sizes=\"auto, (max-width: 583px) 100vw, 583px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"594\" height=\"470\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture46.png\" alt=\"\" class=\"wp-image-21955\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture46.png 594w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture46-300x237.png 300w\" sizes=\"auto, (max-width: 594px) 100vw, 594px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"586\" height=\"462\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture47.png\" alt=\"\" class=\"wp-image-21956\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture47.png 586w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture47-300x237.png 300w\" sizes=\"auto, (max-width: 586px) 100vw, 586px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"595\" height=\"259\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture48.png\" alt=\"\" class=\"wp-image-21957\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture48.png 595w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture48-300x131.png 300w\" sizes=\"auto, (max-width: 595px) 100vw, 595px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"587\" height=\"469\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture49.png\" alt=\"\" class=\"wp-image-21958\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture49.png 587w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture49-300x240.png 300w\" sizes=\"auto, (max-width: 587px) 100vw, 587px\" \/><\/figure>\n\n\n\n<p>Then I had a look on the specified file in the error and I deinstalled the agents on the corresponding servers<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>oracle@oemserverp01:\/u00\/app\/oracle\/product\/13.1.0.0\/swlib\/ &#091;EMRE13C] cat  \/tmp\/OraInstall2023-01-23_09-37-33AM\/extensibility_check\/agent_side_compatibility_check_errors.txt\n============================================================================================================================\nPlug-in                                           Agent                                             Unsupported Version deployed\n============================================================================================================================\nOracle Database                                   dbserver01.example.com:3872                  13.2.1.0.0\nOracle Database                                   dbserver02.example.com:3872                  13.2.2.0.0\noracle@oemserverp01:\/u00\/app\/oracle\/product\/13.1.0.0\/swlib\/ &#091;EMRE13C]\n<\/code><\/pre>\n\n\n\n<p>And then continue the upgrade<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"590\" height=\"472\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture50.png\" alt=\"\" class=\"wp-image-21959\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture50.png 590w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture50-300x240.png 300w\" sizes=\"auto, (max-width: 590px) 100vw, 590px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"591\" height=\"468\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture51.png\" alt=\"\" class=\"wp-image-21960\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture51.png 591w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture51-300x238.png 300w\" sizes=\"auto, (max-width: 591px) 100vw, 591px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"569\" height=\"409\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture52.png\" alt=\"\" class=\"wp-image-21961\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture52.png 569w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture52-300x216.png 300w\" sizes=\"auto, (max-width: 569px) 100vw, 569px\" \/><\/figure>\n\n\n\n<p>Execute as required the root.sh file<\/p>\n\n\n\n<pre class=\"wp-block-code\"><code>&#091;root@oemserverp01 ~]# \/u00\/app\/oracle\/product\/13.5.0.0\/omsr5\/allroot.sh\n\nStarting to execute allroot.sh .........\n\nStarting to execute \/u00\/app\/oracle\/product\/13.5.0.0\/omsr5\/root.sh ......\nCheck \/u00\/app\/oracle\/product\/13.5.0.0\/omsr5\/install\/root_oemserverp01.example.com_2023-01-23_12-06-44.log for the output of root script\nFinished execution of  \/u00\/app\/oracle\/product\/13.5.0.0\/omsr5\/root.sh ......\n\n\n&#091;root@oemserverp01 ~]#\n<\/code><\/pre>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"596\" height=\"469\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture53.png\" alt=\"\" class=\"wp-image-21962\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture53.png 596w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture53-300x236.png 300w\" sizes=\"auto, (max-width: 596px) 100vw, 596px\" \/><\/figure>\n\n\n\n<p>After the end of the process we can validate the new version of our OEM<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"442\" height=\"253\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture54.png\" alt=\"\" class=\"wp-image-21963\" srcset=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture54.png 442w, https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture54-300x172.png 300w\" sizes=\"auto, (max-width: 442px) 100vw, 442px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>Hope this may help. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>By Mouhamadou Diaw Upgrading Enterprise Manger Cloud Control can be tricky. In this blog I am describing an upgrade I did for a client. The source version is OEM13c R4 And the target version will be EM13c R5 Before starting I did following tasks -Copy the key in the repository -set the parameter &#8220;_allow_insert_with_update_check&#8221; to [&hellip;]<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[229,198,59],"tags":[2819,2820,96,2818,2821,2822],"type_dbi":[],"class_list":["post-21931","post","type-post","status-publish","format-standard","hentry","category-database-administration-monitoring","category-database-management","category-oracle","tag-oem-13c-r4","tag-oem-13c-r5","tag-oracle","tag-oracle-enterprice-manager-13c","tag-oracle-grid-control-13c","tag-upgrade-oem"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Upgrade OEM 13c from R4 to R5 - dbi Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Upgrade OEM 13c from R4 to R5\" \/>\n<meta property=\"og:description\" content=\"By Mouhamadou Diaw Upgrading Enterprise Manger Cloud Control can be tricky. In this blog I am describing an upgrade I did for a client. The source version is OEM13c R4 And the target version will be EM13c R5 Before starting I did following tasks -Copy the key in the repository -set the parameter &#8220;_allow_insert_with_update_check&#8221; to [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/\" \/>\n<meta property=\"og:site_name\" content=\"dbi Blog\" \/>\n<meta property=\"article:published_time\" content=\"2023-01-24T18:42:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-20T08:22:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png\" \/>\n<meta name=\"author\" content=\"Oracle Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Oracle Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/\"},\"author\":{\"name\":\"Oracle Team\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/66ab87129f2d357f09971bc7936a77ee\"},\"headline\":\"Upgrade OEM 13c from R4 to R5\",\"datePublished\":\"2023-01-24T18:42:54+00:00\",\"dateModified\":\"2023-06-20T08:22:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/\"},\"wordCount\":162,\"commentCount\":1,\"image\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png\",\"keywords\":[\"OEM 13c R4\",\"OEM 13c R5\",\"Oracle\",\"Oracle Enterprice Manager 13c\",\"Oracle grid control 13c\",\"Upgrade OEM\"],\"articleSection\":[\"Database Administration &amp; Monitoring\",\"Database management\",\"Oracle\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/\",\"name\":\"Upgrade OEM 13c from R4 to R5 - dbi Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png\",\"datePublished\":\"2023-01-24T18:42:54+00:00\",\"dateModified\":\"2023-06-20T08:22:43+00:00\",\"author\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/66ab87129f2d357f09971bc7936a77ee\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png\",\"contentUrl\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png\",\"width\":442,\"height\":247},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.dbi-services.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Upgrade OEM 13c from R4 to R5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#website\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/\",\"name\":\"dbi Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.dbi-services.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/66ab87129f2d357f09971bc7936a77ee\",\"name\":\"Oracle Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/f711f7cd2c9b09bf2627133755b569fb5be0694810cfd33033bdd095fedba86d?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/f711f7cd2c9b09bf2627133755b569fb5be0694810cfd33033bdd095fedba86d?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/f711f7cd2c9b09bf2627133755b569fb5be0694810cfd33033bdd095fedba86d?s=96&d=mm&r=g\",\"caption\":\"Oracle Team\"},\"url\":\"https:\/\/www.dbi-services.com\/blog\/author\/oracle-team\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Upgrade OEM 13c from R4 to R5 - dbi Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/","og_locale":"en_US","og_type":"article","og_title":"Upgrade OEM 13c from R4 to R5","og_description":"By Mouhamadou Diaw Upgrading Enterprise Manger Cloud Control can be tricky. In this blog I am describing an upgrade I did for a client. The source version is OEM13c R4 And the target version will be EM13c R5 Before starting I did following tasks -Copy the key in the repository -set the parameter &#8220;_allow_insert_with_update_check&#8221; to [&hellip;]","og_url":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/","og_site_name":"dbi Blog","article_published_time":"2023-01-24T18:42:54+00:00","article_modified_time":"2023-06-20T08:22:43+00:00","og_image":[{"url":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png","type":"","width":"","height":""}],"author":"Oracle Team","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Oracle Team","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#article","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/"},"author":{"name":"Oracle Team","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/66ab87129f2d357f09971bc7936a77ee"},"headline":"Upgrade OEM 13c from R4 to R5","datePublished":"2023-01-24T18:42:54+00:00","dateModified":"2023-06-20T08:22:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/"},"wordCount":162,"commentCount":1,"image":{"@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png","keywords":["OEM 13c R4","OEM 13c R5","Oracle","Oracle Enterprice Manager 13c","Oracle grid control 13c","Upgrade OEM"],"articleSection":["Database Administration &amp; Monitoring","Database management","Oracle"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/","url":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/","name":"Upgrade OEM 13c from R4 to R5 - dbi Blog","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage"},"image":{"@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png","datePublished":"2023-01-24T18:42:54+00:00","dateModified":"2023-06-20T08:22:43+00:00","author":{"@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/66ab87129f2d357f09971bc7936a77ee"},"breadcrumb":{"@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#primaryimage","url":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png","contentUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2023\/01\/Picture01.png","width":442,"height":247},{"@type":"BreadcrumbList","@id":"https:\/\/www.dbi-services.com\/blog\/upgrade-oem-13c-from-r4-to-r5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.dbi-services.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Upgrade OEM 13c from R4 to R5"}]},{"@type":"WebSite","@id":"https:\/\/www.dbi-services.com\/blog\/#website","url":"https:\/\/www.dbi-services.com\/blog\/","name":"dbi Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dbi-services.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/66ab87129f2d357f09971bc7936a77ee","name":"Oracle Team","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/f711f7cd2c9b09bf2627133755b569fb5be0694810cfd33033bdd095fedba86d?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/f711f7cd2c9b09bf2627133755b569fb5be0694810cfd33033bdd095fedba86d?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/f711f7cd2c9b09bf2627133755b569fb5be0694810cfd33033bdd095fedba86d?s=96&d=mm&r=g","caption":"Oracle Team"},"url":"https:\/\/www.dbi-services.com\/blog\/author\/oracle-team\/"}]}},"_links":{"self":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/21931","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/comments?post=21931"}],"version-history":[{"count":9,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/21931\/revisions"}],"predecessor-version":[{"id":26149,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/21931\/revisions\/26149"}],"wp:attachment":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/media?parent=21931"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/categories?post=21931"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/tags?post=21931"},{"taxonomy":"type","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/type_dbi?post=21931"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}