{"id":14285,"date":"2020-07-23T12:11:03","date_gmt":"2020-07-23T10:11:03","guid":{"rendered":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/"},"modified":"2020-07-23T12:11:03","modified_gmt":"2020-07-23T10:11:03","slug":"control-m-em-sending-alert-to-snmp","status":"publish","type":"post","link":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/","title":{"rendered":"Control-M\/EM Sending alert to SNMP"},"content":{"rendered":"<p>Hello everybody, today we will see how to send Control-M alerts to a central monitoring software<\/p>\n<h3>Introduction<\/h3>\n<p>The aim is to send alerts and logs from Control-M to an event manager system such as Patrol\/ BMC Truesight or Nagios.<br \/>\nWe will see together how to link Control-M to a central monitoring tool,and for that,Control-M admin and monitoring admin must work hand in hand &#x1f60a;.So let&#8217;s start!<\/p>\n<p><u><strong>Copy the Control-M\/EM MIB file to your SNMP server:<\/strong><\/u><\/p>\n<p>First, we must copy the MIB file to the\u00a0 SNMP server (send it to the monitoring application admin as he will have to use it for his monitoring tool&#8217;s configuration)<br \/>\n<strong>Control-M EM _DIR\\Data\\ BMC-CONTROLMEM-MIB.txt<\/strong><br \/>\nThe<em><strong> BMC-CONTROLMEM-MIB.txt <\/strong><\/em>contains SNMP variable and trap format that Control-M\/EM uses to send alerts to an event management system via SNMP<strong>\u00a0<\/strong><br \/>\nFor more details follow this link:<br \/>\n<a href=\"http:\/\/documents.bmc.com\/supportu\/9.0.19\/help\/Main_help\/en-US\/index.htm#45731.htm\">http:\/\/documents.bmc.com\/supportu\/9.0.19\/help\/Main_help\/en-US\/index.htm#45731.htm<\/a><br \/>\nConfigure ControlM\/EM the system parameters<br \/>\nReminder on Alerts and Xalerts:<br \/>\nAlerts and Xalerts can be sent to a central monitoring tool,trigger a script and pass infos as parameters and of course be configured to send notifications when a problem occurs ( more details on bmc support site )<\/p>\n<p><strong><u>Alerts:<\/u><\/strong><br \/>\n-Alerts can receive shouts from jobs (must be configured on the job)<br \/>\n-Alerts can display communication messages such as agent availability or communication to Control-M\/Server errors<\/p>\n<p><strong><u>Exceptions alerts (Xalerts):<\/u><\/strong><br \/>\n-Generated by the EM server of internal errors from components<br \/>\n-We can view these alerts under Manage\/Exception panel<br \/>\nFrom the CCM, define the following system parameters, as described in <a href=\"http:\/\/documents.bmc.com\/supportu\/9.0.19\/help\/Main_help\/en-US\/index.htm#ctmSysParamsForm.htm\">Defining Control-M\/EM system parameters<\/a>:<\/p>\n<ul>\n<li><strong>SNMPHost<\/strong>: Define the hostname of the SNMP server where the alerts are sent.<\/li>\n<li><strong>SNMPSendActive<\/strong>: Change the value to 1 to generate SNMP messages for Active Alerts.<\/li>\n<li><strong>SendSNMP<\/strong>: Change the value to 0 to send alerts to SNMP server only.<\/li>\n<li><strong>SendAlertNotesSnmp<\/strong>: Change the value to 1 if you want to send the NOTES field to the SNMP server.<\/li>\n<li><strong>XAlertsEnableSending<\/strong>: Change the value to 1 to enable xAlert sending. Note that default value is 1.<\/li>\n<li><strong>XAlertsSnmpHosts<\/strong>: Define the hostname of the SNMP server where the xAlerts are sent.<\/li>\n<li><strong>XalertsSendSnmp<\/strong>: Change the value to 1 to send xAlerts to SNMP server only (you can also define it to send Xalerts to a script or both.) For more information about Alert parameters, see <a href=\"http:\/\/documents.bmc.com\/supportu\/9.0.19\/help\/Main_help\/en-US\/index.htm#2283.htm\">Control-M\/EM general parameters<\/a>.<\/li>\n<\/ul>\n<p>To proceed, we will use the Control-M Configuration Manager and configure it from Control-M\/EM the system parameters part:<br \/>\n<a href=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40562\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_1.png\" alt=\"\" width=\"1115\" height=\"264\" \/><\/a><br \/>\nThe search bar allows you to display every parameter linked to SNMP and alert sending<br \/>\n<a href=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_3_hostandscript.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40564\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_3_hostandscript.png\" alt=\"\" width=\"1116\" height=\"186\" \/><\/a><br \/>\nMost important fields are:<br \/>\n<strong>Name<\/strong>: indicate the name of the parameter<br \/>\n<strong>Description<\/strong>: indicate the parameter role<br \/>\n<strong>Refresh method<\/strong>: indicate if Control-M component should be restarted (<strong>recycle<\/strong>) for changes to take effect<br \/>\nFollowing this information, we will activate SNMP trap sending and define the host corresponding to the monitoring machine<br \/>\nEspecially we will focus on configuring and sending SNMP\u00a0 traps to the central monitoring tool by adding it&#8217;s address in the appropriate field<br \/>\n<a href=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_srvaddress.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40561\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_srvaddress.png\" alt=\"\" width=\"1157\" height=\"675\" \/><\/a><br \/>\n<strong><u>Important<\/u><\/strong><br \/>\nNote that the refresh method is a critical point for changes to take effect:<\/p>\n<p><strong>Automatic<\/strong>: no action needed for the change to take effect<br \/>\n<strong>Manual<\/strong>: action needed for the change to take effect<br \/>\n<strong>Recycle<\/strong>: Cycle the related component for the change to take effect<br \/>\nRecycle GATEWAY<br \/>\nHere we will have to recycle components for the changes to take effect:<br \/>\nSelect on the gateway the option \u201crecycle\u201d<br \/>\n<a href=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40559\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png\" alt=\"\" width=\"1118\" height=\"190\" \/><\/a><br \/>\nOnce the gateway indicates connected status the changes are taken in account<br \/>\nTest to send alert to central monitoring tool.<br \/>\nAs from Control-M side the SNMP sending configuration is done, the final step is to test by sending an alert to the alert window with a failing test job for example<br \/>\nCheck if the central monitoring server is receiving the trap (synchronize with the monitoring application administrator). If your administrator confirm the trap is received then everything is ok<br \/>\n<a href=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_pannel.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-40560\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_pannel.png\" alt=\"\" width=\"1160\" height=\"460\" \/><\/a><\/p>\n<h3>Conclusion<\/h3>\n<p>Now you know how to send traps to an external monitoring tool. For more information and further configuration please go to BMC site and check the documentation<br \/>\nYou can go to the help part of your Control-M workload client., also following this link for example you can have the SNMP trap format:<br \/>\n<a href=\"http:\/\/documents.bmc.com\/supportu\/9.0.19\/help\/Main_help\/en-US\/index.htm#45731.htm\">http:\/\/documents.bmc.com\/supportu\/9.0.19\/help\/Main_help\/en-US\/index.htm#45731.htm<\/a><br \/>\nFeel free to check <a href=\"https:\/\/www.dbi-services.com\/bloggers\/\">dbi-services blogger<\/a>s and share with us you experience and tips of BMC Control-M!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hello everybody, today we will see how to send Control-M alerts to a central monitoring software Introduction The aim is to send alerts and logs from Control-M to an event manager system such as Patrol\/ BMC Truesight or Nagios. We will see together how to link Control-M to a central monitoring tool,and for that,Control-M admin&hellip;&nbsp;<\/p>\n","protected":false},"author":40,"featured_media":14289,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","neve_meta_reading_time":"","_themeisle_gutenberg_block_has_review":false,"footnotes":""},"categories":[1256],"tags":[],"class_list":["post-14285","post","type-post","status-publish","format-standard","has-post-thumbnail","category-control-m"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Control-M\/EM Sending alert to SNMP - dbi services Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Control-M\/EM Sending alert to SNMP\" \/>\n<meta property=\"og:description\" content=\"Hello everybody, today we will see how to send Control-M alerts to a central monitoring software Introduction The aim is to send alerts and logs from Control-M to an event manager system such as Patrol\/ BMC Truesight or Nagios. We will see together how to link Control-M to a central monitoring tool,and for that,Control-M admin&hellip;&nbsp;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/\" \/>\n<meta property=\"og:site_name\" content=\"dbi services Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/dbiservices\/\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-23T10:11:03+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1580\" \/>\n\t<meta property=\"og:image:height\" content=\"269\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Middleware Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@dbiservices\" \/>\n<meta name=\"twitter:site\" content=\"@dbiservices\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Middleware Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/\"},\"author\":{\"name\":\"Middleware Team\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/#\\\/schema\\\/person\\\/8a0bfec3c3bd1f27d3d452eaa592bfb8\"},\"headline\":\"Control-M\\\/EM Sending alert to SNMP\",\"datePublished\":\"2020-07-23T10:11:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/\"},\"wordCount\":732,\"commentCount\":1,\"publisher\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/SNMP_options_xalerts_gtw.png\",\"articleSection\":[\"Control-M\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/\",\"url\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/\",\"name\":\"Control-M\\\/EM Sending alert to SNMP - dbi services Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/SNMP_options_xalerts_gtw.png\",\"datePublished\":\"2020-07-23T10:11:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/SNMP_options_xalerts_gtw.png\",\"contentUrl\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/04\\\/SNMP_options_xalerts_gtw.png\",\"width\":1580,\"height\":269},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/control-m-em-sending-alert-to-snmp\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Control-M\\\/EM Sending alert to SNMP\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/\",\"name\":\"dbi services Blog\",\"description\":\"#BeSharing\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/#organization\",\"name\":\"dbi services\",\"url\":\"https:\\\/\\\/www.dbi-services.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/dbi-services-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/dbi-services-logo.png\",\"width\":512,\"height\":512,\"caption\":\"dbi services\"},\"image\":{\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/dbiservices\\\/\",\"https:\\\/\\\/x.com\\\/dbiservices\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/dbi-services\\\/\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/dbiservices\"],\"description\":\"Swiss IT consulting and services company specialized in efficient data infrastructures and platforms: databases, application servers, cloud, DevOps, digitalization, analytics, data quality and monitoring. Headquartered in Del\u00e9mont with offices in Nyon, Basel, Bern and Zurich.\",\"email\":\"info@dbi-services.com\",\"telephone\":\"+41 32 422 96 00\",\"legalName\":\"dbi services SA\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/#\\\/schema\\\/person\\\/8a0bfec3c3bd1f27d3d452eaa592bfb8\",\"name\":\"Middleware Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddcae7ba0f9d1a0e7ae707f0e689e4a9c95bb48ec49c8e6d9cc86d43f4121cb6?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddcae7ba0f9d1a0e7ae707f0e689e4a9c95bb48ec49c8e6d9cc86d43f4121cb6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddcae7ba0f9d1a0e7ae707f0e689e4a9c95bb48ec49c8e6d9cc86d43f4121cb6?s=96&d=mm&r=g\",\"caption\":\"Middleware Team\"},\"description\":\"Posts published under the Middleware Team account are collective contributions by the dbi services middleware and enterprise content management consultants. The practice covers ECM platforms such as OpenText Documentum, Alfresco, and M-Files, as well as application servers and integration technologies including WebLogic, JBoss, Tomcat, and the Elastic Stack, from architecture and deployment to operations under service level agreements.\",\"url\":\"https:\\\/\\\/www.dbi-services.com\\\/blog\\\/author\\\/middleware-team\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Control-M\/EM Sending alert to SNMP - dbi services Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/","og_locale":"en_US","og_type":"article","og_title":"Control-M\/EM Sending alert to SNMP","og_description":"Hello everybody, today we will see how to send Control-M alerts to a central monitoring software Introduction The aim is to send alerts and logs from Control-M to an event manager system such as Patrol\/ BMC Truesight or Nagios. We will see together how to link Control-M to a central monitoring tool,and for that,Control-M admin&hellip;&nbsp;","og_url":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/","og_site_name":"dbi services Blog","article_publisher":"https:\/\/www.facebook.com\/dbiservices\/","article_published_time":"2020-07-23T10:11:03+00:00","og_image":[{"width":1580,"height":269,"url":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png","type":"image\/png"}],"author":"Middleware Team","twitter_card":"summary_large_image","twitter_creator":"@dbiservices","twitter_site":"@dbiservices","twitter_misc":{"Written by":"Middleware Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#article","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/"},"author":{"name":"Middleware Team","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/8a0bfec3c3bd1f27d3d452eaa592bfb8"},"headline":"Control-M\/EM Sending alert to SNMP","datePublished":"2020-07-23T10:11:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/"},"wordCount":732,"commentCount":1,"publisher":{"@id":"https:\/\/www.dbi-services.com\/#organization"},"image":{"@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png","articleSection":["Control-M"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/","url":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/","name":"Control-M\/EM Sending alert to SNMP - dbi services Blog","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#primaryimage"},"image":{"@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png","datePublished":"2020-07-23T10:11:03+00:00","breadcrumb":{"@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#primaryimage","url":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png","contentUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2022\/04\/SNMP_options_xalerts_gtw.png","width":1580,"height":269},{"@type":"BreadcrumbList","@id":"https:\/\/www.dbi-services.com\/blog\/control-m-em-sending-alert-to-snmp\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.dbi-services.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Control-M\/EM Sending alert to SNMP"}]},{"@type":"WebSite","@id":"https:\/\/www.dbi-services.com\/blog\/#website","url":"https:\/\/www.dbi-services.com\/blog\/","name":"dbi services Blog","description":"#BeSharing","publisher":{"@id":"https:\/\/www.dbi-services.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dbi-services.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.dbi-services.com\/#organization","name":"dbi services","url":"https:\/\/www.dbi-services.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2026\/09\/dbi-services-logo.png","contentUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/2026\/09\/dbi-services-logo.png","width":512,"height":512,"caption":"dbi services"},"image":{"@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/dbiservices\/","https:\/\/x.com\/dbiservices","https:\/\/www.linkedin.com\/company\/dbi-services\/","https:\/\/www.youtube.com\/user\/dbiservices"],"description":"Swiss IT consulting and services company specialized in efficient data infrastructures and platforms: databases, application servers, cloud, DevOps, digitalization, analytics, data quality and monitoring. Headquartered in Del\u00e9mont with offices in Nyon, Basel, Bern and Zurich.","email":"info@dbi-services.com","telephone":"+41 32 422 96 00","legalName":"dbi services SA"},{"@type":"Person","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/8a0bfec3c3bd1f27d3d452eaa592bfb8","name":"Middleware Team","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ddcae7ba0f9d1a0e7ae707f0e689e4a9c95bb48ec49c8e6d9cc86d43f4121cb6?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ddcae7ba0f9d1a0e7ae707f0e689e4a9c95bb48ec49c8e6d9cc86d43f4121cb6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ddcae7ba0f9d1a0e7ae707f0e689e4a9c95bb48ec49c8e6d9cc86d43f4121cb6?s=96&d=mm&r=g","caption":"Middleware Team"},"description":"Posts published under the Middleware Team account are collective contributions by the dbi services middleware and enterprise content management consultants. The practice covers ECM platforms such as OpenText Documentum, Alfresco, and M-Files, as well as application servers and integration technologies including WebLogic, JBoss, Tomcat, and the Elastic Stack, from architecture and deployment to operations under service level agreements.","url":"https:\/\/www.dbi-services.com\/blog\/author\/middleware-team\/"}]}},"_links":{"self":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/14285","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/users\/40"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/comments?post=14285"}],"version-history":[{"count":0,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/14285\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/media\/14289"}],"wp:attachment":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/media?parent=14285"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/categories?post=14285"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/tags?post=14285"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}