{"id":11397,"date":"2018-07-05T16:55:27","date_gmt":"2018-07-05T14:55:27","guid":{"rendered":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/"},"modified":"2018-07-05T16:55:27","modified_gmt":"2018-07-05T14:55:27","slug":"oda-fiber-interface-link-detection-issue","status":"publish","type":"post","link":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/","title":{"rendered":"ODA fiber interface link detection issue"},"content":{"rendered":"<p>Configuring fiber interfaces during an ODA installation can sometime been challenging. The configuration can depend on the kind of gigabit interface converter (GBIC) and switch been used. In this blog, I would like to show a real case faced during one of our customer deployment, and come with a solution.<\/p>\n<p><!--more--><\/p>\n<h2>Problem<\/h2>\n<p>We were facing link detection issue when using the GBIC converter delivered by ORACLE, although using a CISCO GBIC converter could make the link available.<br \/>\nem2 interface was used with a CISCO GBIC.<br \/>\nem3 interface was used with an ORACLE GBIC.<\/p>\n<pre class=\"brush: bash; gutter: true; first-line: 1\">[root@TEST1 tmp]# ethtool em2\nSettings for em2:\n        Supported ports: [ FIBRE ]\n        Supported link modes:   1000baseT\/Full\n                                10000baseT\/Full\n        Supported pause frame use: Symmetric Receive-only\n        Supports auto-negotiation: Yes\n        Advertised link modes:  1000baseT\/Full\n                                10000baseT\/Full\n        Advertised pause frame use: No\n        Advertised auto-negotiation: Yes\n        Speed: 10000Mb\/s\n        Duplex: Full\n        Port: FIBRE\n        PHYAD: 1\n        Transceiver: internal\n        Auto-negotiation: on\n        Supports Wake-on: d\n        Wake-on: d\n        Current message level: 0x00000000 (0)\n\n        Link detected: yes\n        \n[root@TEST1 tmp]# ethtool em3\nSettings for em3:\n        Supported ports: [ FIBRE ]\n        Supported link modes:   1000baseT\/Full\n                                10000baseT\/Full\n        Supported pause frame use: Symmetric Receive-only\n        Supports auto-negotiation: Yes\n        Advertised link modes:  1000baseT\/Full\n                                10000baseT\/Full\n        Advertised pause frame use: No\n        Advertised auto-negotiation: Yes\n        Speed: Unknown!\n        Duplex: Unknown! (255)\n        Port: FIBRE\n        PHYAD: 1\n        Transceiver: internal\n        Auto-negotiation: on\n        Supports Wake-on: d\n        Wake-on: d\n        Current message level: 0x00000000 (0)\n\n        Link detected: no\n\n<\/pre>\n<p>&nbsp;<\/p>\n<h2>Solution<\/h2>\n<p>Forcing the interface on 10 Gb and configuring auto-negotiation to false could solve the link detection issue with the ORACLE GBIC converter.<br \/>\nThis has been performed by updating both ifcfg-em2 and ifcfg-em3 (stored in \/etc\/sysconfig\/network-scripts) with :<\/p>\n<pre class=\"brush: bash; gutter: true; first-line: 1\">ETHTOOL_OPTS=\"speed 10000 duplex full autoneg off\"<\/pre>\n<p>&nbsp;<\/p>\n<p>Both links could then be detected successfully.<\/p>\n<pre class=\"brush: bash; gutter: true; first-line: 1\">[root@TEST1 ~]# ethtool em2\nSettings for em2:\n        Supported ports: [ FIBRE ]\n        Supported link modes:   1000baseT\/Full\n                                10000baseT\/Full\n        Supported pause frame use: Symmetric Receive-only\n        Supports auto-negotiation: Yes\n        Advertised link modes:  Not reported\n        Advertised pause frame use: No\n        Advertised auto-negotiation: No\n        Speed: 10000Mb\/s\n        Duplex: Full\n        Port: FIBRE\n        PHYAD: 1\n        Transceiver: internal\n        Auto-negotiation: off\n        Supports Wake-on: d\n        Wake-on: d\n        Current message level: 0x00000000 (0)\n\n        Link detected: yes\n        \n[root@TEST1 ~]# ethtool em3\nSettings for em3:\n        Supported ports: [ FIBRE ]\n        Supported link modes:   1000baseT\/Full\n                                10000baseT\/Full\n        Supported pause frame use: Symmetric Receive-only\n        Supports auto-negotiation: Yes\n        Advertised link modes:  Not reported\n        Advertised pause frame use: No\n        Advertised auto-negotiation: No\n        Speed: 10000Mb\/s\n        Duplex: Full\n        Port: FIBRE\n        PHYAD: 1\n        Transceiver: internal\n        Auto-negotiation: off\n        Supports Wake-on: d\n        Wake-on: d\n        Current message level: 0x00000000 (0)\n\n        Link detected: yes<\/pre>\n<p>&nbsp;<\/p>\n<h2>SFP28 Ethernet Controller firmware upgrade<\/h2>\n<p>The firmware version we were running is the 20.06.04.06.<\/p>\n<pre class=\"brush: bash; gutter: true; first-line: 1\">[root@TEST1 ~]# ethtool -i em3\ndriver: bnxt_en\nversion: 1.8.0\nfirmware-version: 20.6.141\/1.8.1 pkg 20.06.04.06\nbus-info: 0000:18:00.1\nsupports-statistics: yes\nsupports-test: yes\nsupports-eeprom-access: yes\nsupports-register-dump: no\nsupports-priv-flags: no<\/pre>\n<p>In case of further trouble, a firmware upgrade to\u00a020.08.01.14 version can help, as described in following MOS note.<br \/>\nUsing the onboard SFP28 ports on an ODA X7-2 server node (Doc ID 2373070.1)<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Configuring fiber interfaces during an ODA installation can sometime been challenging. The configuration can depend on the kind of gigabit interface converter (GBIC) and switch been used. In this blog, I would like to show a real case faced during one of our customer deployment, and come with a solution.<\/p>\n","protected":false},"author":48,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[229,59],"tags":[79],"type_dbi":[],"class_list":["post-11397","post","type-post","status-publish","format-standard","hentry","category-database-administration-monitoring","category-oracle","tag-oda"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>ODA fiber interface link detection issue - dbi Blog<\/title>\n<meta name=\"description\" content=\"This blog describe a common link detection issue and solution when using GBIB.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ODA fiber interface link detection issue\" \/>\n<meta property=\"og:description\" content=\"This blog describe a common link detection issue and solution when using GBIB.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/\" \/>\n<meta property=\"og:site_name\" content=\"dbi Blog\" \/>\n<meta property=\"article:published_time\" content=\"2018-07-05T14:55:27+00:00\" \/>\n<meta name=\"author\" content=\"Marc Wagner\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marc Wagner\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/\"},\"author\":{\"name\":\"Marc Wagner\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/225d9884b8467ead9a872823acb14628\"},\"headline\":\"ODA fiber interface link detection issue\",\"datePublished\":\"2018-07-05T14:55:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/\"},\"wordCount\":191,\"commentCount\":0,\"keywords\":[\"ODA\"],\"articleSection\":[\"Database Administration &amp; Monitoring\",\"Oracle\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/\",\"name\":\"ODA fiber interface link detection issue - dbi Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#website\"},\"datePublished\":\"2018-07-05T14:55:27+00:00\",\"author\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/225d9884b8467ead9a872823acb14628\"},\"description\":\"This blog describe a common link detection issue and solution when using GBIB.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.dbi-services.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ODA fiber interface link detection issue\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#website\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/\",\"name\":\"dbi Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.dbi-services.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/225d9884b8467ead9a872823acb14628\",\"name\":\"Marc Wagner\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/a873cc6e7fbdbbcbdbcaf5dbded14ad9a77b2ec2c3e03b4d724ed33d35d5f328?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/a873cc6e7fbdbbcbdbcaf5dbded14ad9a77b2ec2c3e03b4d724ed33d35d5f328?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/a873cc6e7fbdbbcbdbcaf5dbded14ad9a77b2ec2c3e03b4d724ed33d35d5f328?s=96&d=mm&r=g\",\"caption\":\"Marc Wagner\"},\"url\":\"https:\/\/www.dbi-services.com\/blog\/author\/marc-wagner\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"ODA fiber interface link detection issue - dbi Blog","description":"This blog describe a common link detection issue and solution when using GBIB.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/","og_locale":"en_US","og_type":"article","og_title":"ODA fiber interface link detection issue","og_description":"This blog describe a common link detection issue and solution when using GBIB.","og_url":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/","og_site_name":"dbi Blog","article_published_time":"2018-07-05T14:55:27+00:00","author":"Marc Wagner","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Marc Wagner","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#article","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/"},"author":{"name":"Marc Wagner","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/225d9884b8467ead9a872823acb14628"},"headline":"ODA fiber interface link detection issue","datePublished":"2018-07-05T14:55:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/"},"wordCount":191,"commentCount":0,"keywords":["ODA"],"articleSection":["Database Administration &amp; Monitoring","Oracle"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/","url":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/","name":"ODA fiber interface link detection issue - dbi Blog","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/#website"},"datePublished":"2018-07-05T14:55:27+00:00","author":{"@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/225d9884b8467ead9a872823acb14628"},"description":"This blog describe a common link detection issue and solution when using GBIB.","breadcrumb":{"@id":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.dbi-services.com\/blog\/oda-fiber-interface-link-detection-issue\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.dbi-services.com\/blog\/"},{"@type":"ListItem","position":2,"name":"ODA fiber interface link detection issue"}]},{"@type":"WebSite","@id":"https:\/\/www.dbi-services.com\/blog\/#website","url":"https:\/\/www.dbi-services.com\/blog\/","name":"dbi Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dbi-services.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/225d9884b8467ead9a872823acb14628","name":"Marc Wagner","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/a873cc6e7fbdbbcbdbcaf5dbded14ad9a77b2ec2c3e03b4d724ed33d35d5f328?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/a873cc6e7fbdbbcbdbcaf5dbded14ad9a77b2ec2c3e03b4d724ed33d35d5f328?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/a873cc6e7fbdbbcbdbcaf5dbded14ad9a77b2ec2c3e03b4d724ed33d35d5f328?s=96&d=mm&r=g","caption":"Marc Wagner"},"url":"https:\/\/www.dbi-services.com\/blog\/author\/marc-wagner\/"}]}},"_links":{"self":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/11397","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/users\/48"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/comments?post=11397"}],"version-history":[{"count":0,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/11397\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/media?parent=11397"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/categories?post=11397"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/tags?post=11397"},{"taxonomy":"type","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/type_dbi?post=11397"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}