{"id":11053,"date":"2018-03-29T13:48:23","date_gmt":"2018-03-29T11:48:23","guid":{"rendered":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/"},"modified":"2018-03-29T13:48:23","modified_gmt":"2018-03-29T11:48:23","slug":"how-reimaging-detects-the-oda-hardware","status":"publish","type":"post","link":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/","title":{"rendered":"How reimaging detects the ODA hardware?"},"content":{"rendered":"<p>A long time ago, ODA referred to the only model that existed (nearly). Actually, not so long time ago, as ODA X3, X4 and X5 were released between 2013 and 2015. And it was quite the same hardware.<\/p>\n<p>Now there is 3 current models in the X7 range, and they were 4 in the previous generation (X6).<\/p>\n<p>ODA is now divided in 2 main lines. High Availability models, understand 2 nodes and a shared storage like the first generations. And lite models, with only 1 node and local NVMe SSD, obviously more afordable than HA models.<\/p>\n<p>Beginning with X6, lite models came with a brand new ISO for reimaging, including the new odacli, a higher level administration tool (compared to oakcli), and X6-2HA remained with the same ISO as previous gen models.<\/p>\n<p>But now, X7 range saw the adoption of odacli for all models. And if you stick with bare metal, ISO is now the same for reimaging all the range. Quite convenient isn&#8217;t it?<\/p>\n<p>I recently asked myself: how the reimaging process determines the correct model?<\/p>\n<p>First of all, you can look at your ODA model with odaadmcli:<\/p>\n<pre class=\"brush: actionscript3; gutter: true; first-line: 1\">odaadmcli show env_hw\nBM ODA X7-2 Medium<\/pre>\n<p>&nbsp;<\/p>\n<p>As you may know, reimaging process is fully automatic, and you have nothing to provide unless the correct ISO.<\/p>\n<p>If ODA X7-S has only one Xeon CPU, nodes for ODA X7-M and X7-2HA are barelly the same, so what differs from them?<\/p>\n<p>I first thought it was somewhere hardcoded, but it doesn&#8217;t seems to. ODA X7 is just the same hardware as the multi-purpose Oracle Server X7-2. Among the ISO files, I found a script that detects correct model by counting the number of local NVMe SSD (quite smart because HA model has only M2 SSD disks for the system and no NVMe SSDs), but it was not used during the reimaging&#8230;<\/p>\n<p>Looking deeper on the system side, I found that model was simply part of the grub.conf boot options:<\/p>\n<pre class=\"brush: actionscript3; gutter: true; first-line: 1\">kernel \/vmlinuz-4.1.12-94.4.1.el6uek.x86_64 ro root=\/dev\/mapper\/VolGroupSys-LogVolRoot rd_NO_LUKS rd_MD_UUID=1ee3fdbc:3fdcdcf4:3a28f182:1a674b68 rd_LVM_LV=VolGroupSys\/LogVolRoot rd_LVM_LV=VolGroupSys\/LogVolSwap SYSFONT=latarcyrheb-sun16 pci=noaer crashkernel=256M@64M loglevel=3 panic=60 transparent_hugepage=never biosdevname=1 ipv6.disable=1 debug audit=1 intel_idle.max_cstate=1 nofloppy nomce numa=off console=ttyS0,115200n8 console=tty0 KEYBOARDTYPE=pc KEYTABLE=us rd_NO_DM LANG=en_US.UTF-8 PRODUCT=ORACLE_SERVER_X7-2 TYPE=X7_2_LITE_M<\/pre>\n<p>I discovered that odacli is based on this information. If you remove these settings, your ODA will be considered as a HA model, and odacli will crash:<\/p>\n<pre class=\"brush: actionscript3; gutter: true; first-line: 1\">DCS-10002: Invalid hardware platform<\/pre>\n<p>Okay, but it doesn&#8217;t tell me how the reimaging process decides which model to put in the grub.conf parameters&#8230;<\/p>\n<p>Actually, grub.conf is configured at deployment with something from the ILOM, the &#8220;SP System identifier&#8221; located in the settings under the ILOM hostname:<\/p>\n<p><a href=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-22208\" src=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png\" alt=\"blog_X7_SP_identifier\" width=\"300\" height=\"171\" \/><\/a><\/p>\n<p>As you can see, this field can be edited, and you can put everything in it (didn&#8217;t tried EXADATA&#8230;). Unfortunatly, it&#8217;s just below the &#8220;SP Hostname&#8221; and some people would probably like to change this identifier in the same time they are feeding the hostname. But it&#8217;s a bad idea because your ODA would not be correctly deployed for the next time you&#8217;ll need to reimage!<\/p>\n<p>Be aware of that and please do not touch this identifier. Keep it as it is.<\/p>\n<p>Notes :<br \/>\n&#8211; reimaging was done with patch 23530609 (version 12.2.1.2.0)<br \/>\n&#8211; default hostname for the ODA ILOM is&#8230; the SP System Identifier<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A long time ago, ODA referred to the only model that existed (nearly). Actually, not so long time ago, as ODA X3, X4 and X5 were released between 2013 and 2015. And it was quite the same hardware. Now there is 3 current models in the X7 range, and they were 4 in the previous [&hellip;]<\/p>\n","protected":false},"author":45,"featured_media":11054,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[229],"tags":[79,1327,96,1328,867,1329,1330,1331,1332],"type_dbi":[],"class_list":["post-11053","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-database-administration-monitoring","tag-oda","tag-odacli","tag-oracle","tag-reimaging","tag-x6","tag-x7","tag-x7-2ha","tag-x7-2m","tag-x7-2s"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How reimaging detects the ODA hardware? - dbi Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How reimaging detects the ODA hardware?\" \/>\n<meta property=\"og:description\" content=\"A long time ago, ODA referred to the only model that existed (nearly). Actually, not so long time ago, as ODA X3, X4 and X5 were released between 2013 and 2015. And it was quite the same hardware. Now there is 3 current models in the X7 range, and they were 4 in the previous [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/\" \/>\n<meta property=\"og:site_name\" content=\"dbi Blog\" \/>\n<meta property=\"article:published_time\" content=\"2018-03-29T11:48:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png\" \/>\n\t<meta property=\"og:image:width\" content=\"856\" \/>\n\t<meta property=\"og:image:height\" content=\"489\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"J\u00e9r\u00f4me Dubar\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"J\u00e9r\u00f4me Dubar\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/\"},\"author\":{\"name\":\"J\u00e9r\u00f4me Dubar\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/0fb4bbf128b4cda2f96d662dec2baedd\"},\"headline\":\"How reimaging detects the ODA hardware?\",\"datePublished\":\"2018-03-29T11:48:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/\"},\"wordCount\":507,\"commentCount\":0,\"image\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png\",\"keywords\":[\"ODA\",\"odacli\",\"Oracle\",\"reimaging\",\"X6\",\"X7\",\"X7-2HA\",\"X7-2M\",\"X7-2S\"],\"articleSection\":[\"Database Administration &amp; Monitoring\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/\",\"name\":\"How reimaging detects the ODA hardware? - dbi Blog\",\"isPartOf\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png\",\"datePublished\":\"2018-03-29T11:48:23+00:00\",\"author\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/0fb4bbf128b4cda2f96d662dec2baedd\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png\",\"contentUrl\":\"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png\",\"width\":856,\"height\":489},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/www.dbi-services.com\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How reimaging detects the ODA hardware?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#website\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/\",\"name\":\"dbi Blog\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.dbi-services.com\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/0fb4bbf128b4cda2f96d662dec2baedd\",\"name\":\"J\u00e9r\u00f4me Dubar\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/secure.gravatar.com\/avatar\/efaa5a7def0aa4cdaf49a470fb4a7641a3ea6e378ae1455096a0933f99f46d6b?s=96&d=mm&r=g\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/efaa5a7def0aa4cdaf49a470fb4a7641a3ea6e378ae1455096a0933f99f46d6b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/efaa5a7def0aa4cdaf49a470fb4a7641a3ea6e378ae1455096a0933f99f46d6b?s=96&d=mm&r=g\",\"caption\":\"J\u00e9r\u00f4me Dubar\"},\"description\":\"J\u00e9r\u00f4me Dubar has more than 15 years of experience in the field of Information Technology. Ten years ago, he specialized in the Oracle Database technology. His expertise is focused on database architectures, high availability (RAC), disaster recovery (DataGuard), backups (RMAN), performance analysis and tuning (AWR\/statspack), migration, consolidation and appliances, especially ODA (his main projects during the last years). Prior to joining dbi services, J\u00e9r\u00f4me Dubar worked in a Franco-Belgian IT service company as Database team manager and main consultant for 7 years. He also worked for 5 years in a software editor company as technical consultant across France. He was also teaching Oracle Database lessons for 9 years. J\u00e9r\u00f4me Dubar holds a Computer Engineering degree from the Lille Sciences and Technologies university in northern France. His branch-related experience covers the public sector, retail, industry, banking, health, e-commerce and IT sectors.\",\"url\":\"https:\/\/www.dbi-services.com\/blog\/author\/jerome-dubar\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How reimaging detects the ODA hardware? - dbi Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/","og_locale":"en_US","og_type":"article","og_title":"How reimaging detects the ODA hardware?","og_description":"A long time ago, ODA referred to the only model that existed (nearly). Actually, not so long time ago, as ODA X3, X4 and X5 were released between 2013 and 2015. And it was quite the same hardware. Now there is 3 current models in the X7 range, and they were 4 in the previous [&hellip;]","og_url":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/","og_site_name":"dbi Blog","article_published_time":"2018-03-29T11:48:23+00:00","og_image":[{"width":856,"height":489,"url":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png","type":"image\/png"}],"author":"J\u00e9r\u00f4me Dubar","twitter_card":"summary_large_image","twitter_misc":{"Written by":"J\u00e9r\u00f4me Dubar","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#article","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/"},"author":{"name":"J\u00e9r\u00f4me Dubar","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/0fb4bbf128b4cda2f96d662dec2baedd"},"headline":"How reimaging detects the ODA hardware?","datePublished":"2018-03-29T11:48:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/"},"wordCount":507,"commentCount":0,"image":{"@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png","keywords":["ODA","odacli","Oracle","reimaging","X6","X7","X7-2HA","X7-2M","X7-2S"],"articleSection":["Database Administration &amp; Monitoring"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/","url":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/","name":"How reimaging detects the ODA hardware? - dbi Blog","isPartOf":{"@id":"https:\/\/www.dbi-services.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage"},"image":{"@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage"},"thumbnailUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png","datePublished":"2018-03-29T11:48:23+00:00","author":{"@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/0fb4bbf128b4cda2f96d662dec2baedd"},"breadcrumb":{"@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#primaryimage","url":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png","contentUrl":"https:\/\/www.dbi-services.com\/blog\/wp-content\/uploads\/sites\/2\/2022\/04\/blog_X7_SP_identifier.png","width":856,"height":489},{"@type":"BreadcrumbList","@id":"https:\/\/www.dbi-services.com\/blog\/how-reimaging-detects-the-oda-hardware\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/www.dbi-services.com\/blog\/"},{"@type":"ListItem","position":2,"name":"How reimaging detects the ODA hardware?"}]},{"@type":"WebSite","@id":"https:\/\/www.dbi-services.com\/blog\/#website","url":"https:\/\/www.dbi-services.com\/blog\/","name":"dbi Blog","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.dbi-services.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.dbi-services.com\/blog\/#\/schema\/person\/0fb4bbf128b4cda2f96d662dec2baedd","name":"J\u00e9r\u00f4me Dubar","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/efaa5a7def0aa4cdaf49a470fb4a7641a3ea6e378ae1455096a0933f99f46d6b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/efaa5a7def0aa4cdaf49a470fb4a7641a3ea6e378ae1455096a0933f99f46d6b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/efaa5a7def0aa4cdaf49a470fb4a7641a3ea6e378ae1455096a0933f99f46d6b?s=96&d=mm&r=g","caption":"J\u00e9r\u00f4me Dubar"},"description":"J\u00e9r\u00f4me Dubar has more than 15 years of experience in the field of Information Technology. Ten years ago, he specialized in the Oracle Database technology. His expertise is focused on database architectures, high availability (RAC), disaster recovery (DataGuard), backups (RMAN), performance analysis and tuning (AWR\/statspack), migration, consolidation and appliances, especially ODA (his main projects during the last years). Prior to joining dbi services, J\u00e9r\u00f4me Dubar worked in a Franco-Belgian IT service company as Database team manager and main consultant for 7 years. He also worked for 5 years in a software editor company as technical consultant across France. He was also teaching Oracle Database lessons for 9 years. J\u00e9r\u00f4me Dubar holds a Computer Engineering degree from the Lille Sciences and Technologies university in northern France. His branch-related experience covers the public sector, retail, industry, banking, health, e-commerce and IT sectors.","url":"https:\/\/www.dbi-services.com\/blog\/author\/jerome-dubar\/"}]}},"_links":{"self":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/11053","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/users\/45"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/comments?post=11053"}],"version-history":[{"count":0,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/posts\/11053\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/media\/11054"}],"wp:attachment":[{"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/media?parent=11053"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/categories?post=11053"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/tags?post=11053"},{"taxonomy":"type","embeddable":true,"href":"https:\/\/www.dbi-services.com\/blog\/wp-json\/wp\/v2\/type_dbi?post=11053"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}