Skip to content

Oracle 20c Data Guard : Validating a Fast Start Failover Configuration

By Mouhamadou Diaw

In Oracle 20c, we can now validate a Fast Start Failover configuration with the new command VALIDATE FAST_START FAILOVER. This command will help identifying issues in the configuration. I tested this new feature.
The Fast Start Failover is configured and the observer is running fine as we can see below.

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
DGMGRL> show configuration verbose
Configuration - prod20
  Protection Mode: MaxPerformance
  Members:
  prod20_site1 - Primary database
    prod20_site2 - (*) Physical standby database
  (*) Fast-Start Failover target
  Properties:
    FastStartFailoverThreshold      = '30'
    OperationTimeout                = '30'
    TraceLevel                      = 'USER'
    FastStartFailoverLagLimit       = '30'
    CommunicationTimeout            = '180'
    ObserverReconnect               = '0'
    FastStartFailoverAutoReinstate  = 'TRUE'
    FastStartFailoverPmyShutdown    = 'TRUE'
    BystandersFollowRoleChange      = 'ALL'
    ObserverOverride                = 'FALSE'
    ExternalDestination1            = ''
    ExternalDestination2            = ''
    PrimaryLostWriteAction          = 'CONTINUE'
    ConfigurationWideServiceName    = 'prod20_CFG'
    ConfigurationSimpleName         = 'prod20'
Fast-Start Failover: Enabled in Potential Data Loss Mode
  Lag Limit:          30 seconds
  Threshold:          30 seconds
  Active Target:      prod20_site2
  Potential Targets:  "prod20_site2"
    prod20_site2 valid
  Observer:           oraadserver2
  Shutdown Primary:   TRUE
  Auto-reinstate:     TRUE
  Observer Reconnect: (none)
  Observer Override:  FALSE
Configuration Status:
SUCCESS
DGMGRL>

If we run the command we can see that everything is working and that a failover will happen if needed

1
2
3
4
5
6
7
DGMGRL> VALIDATE FAST_START FAILOVER;
  Fast-Start Failover:  Enabled in Potential Data Loss Mode
  Protection Mode:      MaxPerformance
  Primary:              prod20_site1
  Active Target:        prod20_site2
DGMGRL

Now let’s stop the observer

1
2
3
DGMGRL> stop observer
Observer stopped.

And if we run the Validate command again, we have the following message

1
2
3
4
5
6
7
8
9
10
11
DGMGRL> VALIDATE FAST_START FAILOVER;
  Fast-Start Failover:  Enabled in Potential Data Loss Mode
  Protection Mode:      MaxPerformance
  Primary:              prod20_site1
  Active Target:        prod20_site2
Fast-start failover not possible:
  Fast-start failover observer not started.
DGMGRL>

Let’s work together

Ready to operate at
the next level?

Tell us about your challenge. We’ll bring the depth, the expertise, and the Swiss precision.

Oracle Team

Oracle Team

Posts published under the Oracle Team account are collective contributions by the dbi services Oracle consultants. The practice covers the full Oracle Database lifecycle: architecture, migration and upgrade, high availability with RAC and Data Guard, backup and recovery, performance tuning, and engineered systems such as Oracle Database Appliance and Exadata. The team holds Oracle certifications up to Certified Master level and operates customer platforms under service level agreements.View Author posts

1,009 posts since December 2010

Most read in Oracle

The Oracle posts our readers open most: the all-time favourites, and what is trending right now.

Leave a Comment

Your email address will not be published. Required fields are marked *